Planet-technology 8-Port IP Power Manager IPM-8001 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Planet-technology 8-Port IP Power Manager IPM-8001. Planet Technology 8-Port IP Power Manager IPM-8001 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - User’s Manual

8-Port IP Power Manager IPM-8001 IPM-8002 User’s Manual

Strona 2 - FCC Caution:

Name Function Description LAN Ethernet (LAN) port Enables you to connect IP Power Manager to a LAN or WAN. Console Console port Enables you to con

Strona 3

Chapter 2 Hardware Installation Before you proceed with the installation, it is necessary that you have enough information about the IP Power Manager

Strona 4

2.3 Connecting Digital Outputs The IP Power Manager provides two digital outputs (NO by default) to which you can connect indicators or other outpu

Strona 5 - ...15

2.5 Connecting The Console You can control the output devices and manage their power status through the console port with serial connection. Use th

Strona 6 - Chapter 1 Introduction

control the IP Power Manager from your PC or laptop. When the network has installed a router, you can also use your mobile phone or PDA that is web b

Strona 7 - 1.4 Front and Rear Panel

Chapter 3 User Control Button You can turn on power manually for each of the eight output devices with the control buttons provided under each statu

Strona 8 - Button Description

Chapter 4 Quick Setup When you are first time configure your IP Power Manager. You may refer to this chapter to know how to initial your IP Power Man

Strona 9 - 1.6 Front Panel Interface

5. In default, IP Power Manager is DHCP client enables. If there is no DHCP server in your network. Please click “Set IP” button. Then enter an IP a

Strona 11

Chapter 5 Configure With Console The IP Power Manager has provided a serial port that enables you to configure and control the system through your PC

Strona 12 - 2.4 Connecting EMD

Copyright Copyright© 2006 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribe

Strona 13 - 2.6 Connecting LAN or WAN

4. The Properties window opens. Click” Restore Defaults” to use the default settings. Make sure that the Bits per second field is set to 9600. Clic

Strona 14

- 7 - 6. After enter correct password, you will see the main menu of console interface.

Strona 15

5.2 IP Power Manager Configuration In this option. You can setup the general settings of this IP Power Manager. 5.2.1 System Group In this opt

Strona 16 - Chapter 4 Quick Setup

5.2.2 Control Group - 9 - Option Description Administrator User Name In default, the user name is “admin”. You can change the user name to a simpl

Strona 17

standard Telnet port (23). HTTP Control Enable/Disable the HTTP connection with the IP Power Manager. The user may configure HTTP protocol to use a p

Strona 18

Power on Delay (Seconds) Set power on delay time in seconds. The outlet will turn on after the delay time. Power off Delay (Seconds) Set power off de

Strona 19 - 5.1 Run Hyper Terminal

5.5 Trap Receiver Table This page lists the parameters for SNMP trap receivers (For SNMP Network Management). Option Description IP Address The IP

Strona 20

- 13 - 5.6 Reset Configuration To Default When you would like to reset IP Power Manger to default configuration, please select this option and press

Strona 21

- 14 - 5.8 Exit Select this option to exit Hyper Terminal.

Strona 22 - Option Description

Chapter 6 Web Configuration The IP Power Manager provides a graphic user interface that can be viewed from a web browser such as Internet Explorer.

Strona 23 - 5.2.2 Control Group

Federal Communication Commission (FCC) Radiation Exposure Statement This equipment complies with FCC radiation exposure set forth for an uncontrolled

Strona 24 - 5.3 Outlets Control

- 16 - The left panel provides five options, Power Management, Environment (when EMD connected), System, Network and Logs. When you click the IP P

Strona 25 - 5.4 Access Control

6.1.1.1 Inlet This page shows the associated status and even action of inlet. - 17 - Option Description Status Input Voltage (Volt) The current i

Strona 26 - 5.5 Trap Receiver Table

Input Voltage Threshold Low (Volt) Low threshold of input voltage. When input voltage is lower than this value, IP Power Manager will take action spe

Strona 27

Power Off Delay (Seconds) Set power off delay time in seconds. The outlet will turn off after the delay time. Output Current Threshold (Amp) Set the

Strona 28 - 5.8 Exit

Turn On / Turn Off button Turn digital outputs on or off manually. 6.1.2 Schedule This page allows user to add or remove the IP Power Manager's

Strona 29 - Chapter 6 Web Configuration

Type" is "Special Schedule". Schedule Date (yyyy/mm/dd) Set the date of this schedule. Schedule Time (hh:mm) The time in 24-hour for

Strona 30 - 6.1 Power Management

- 22 - Option Description Sensor Name Configure the name of a sensor (or device) with up to 15 characters.Set Point The threshold of a sensor (Te

Strona 31

EMD Temperature Unit Choose the displayed temperature unit to “Celsius” or “Fahrenheit”. - 23 - 6.2.3 Alarm This page allows user to modify the para

Strona 32

Option Description Configure System System Name This field allows the user to set the value in System name that is defined in MIB-II or to view the

Strona 33

Option Description Index This column provides a reference number for the existence user. User Name The user name which is used to log in the IP P

Strona 34 - 6.1.2 Schedule

TABLE OF CONTENTS CHAPTER 1 INTRODUCTION...1 1.1 PACKAGE CONTENTS...

Strona 35 - 6.2 Environment

6.3.3 Date & Time This page provides the appropriate options below to enable the IP Power Manager date/time to be changed in different methods.

Strona 36

6.3.4 Trap Receivers This page lists the parameters for SNMP trap receivers (For SNMP Network Management). Option Description Index The index numb

Strona 37 - 6.3 System

6.3.6 WOL IP Power Manager has support WOL function to wake your PCs up. This function can help your servers work again after the power interruption.

Strona 38 - 6.3.2 Multi-User

6.3.7 Email Notification This page is allowed when the security level is “Administrator”. There are two groups in this page, one is “General Configur

Strona 39

day in 24-hour format at which time you want the email sent. Email Receivers Tables Mail Account As Administrator, you may enter the email address of

Strona 40 - 6.3.3 Date & Time

Option Description Screen Text This is the description of link name which will display on the menu tree for user's reference. Link Address Th

Strona 41 - 6.3.4 Trap Receivers

Option Description IP Address The IP address of IP Power Manager is dotted format. Default value is "192.168.1.1", and size is 15 characte

Strona 42 - 6.3.6 WOL

firmware. Telnet Connection This is the parameter enabling or disabling the terminal to the server application (Telnet) control process. (e.g. telnet

Strona 43 - 6.3.7 Email Notification

become the management station with the access type set by Administrator. "255.255.255.255" grant the access right to all IP. Access Type Av

Strona 44 - 6.3.8 External Links

Option Description Date (dd/mm/yyyy)This column show the date on which the recording was made. Time (hh:mm:ss) This gives the time in a 24-hour for

Strona 45 - 6.4 Network

CHAPTER 6 WEB CONFIGURATION...15 6.1 POWER MANAGEMENT...

Strona 46 - 6.4.2 Control

Option Description Date (dd/mm/yyyy)This column show the date on which the recording was made. Time (hh:mm:ss) This gives the time in a 24-hour f

Strona 47 - 6.4.3 Access Control

Option Description Clear Log DataPlease select which log you would like to delete and click “Clear”button. Save Log Data You can click the disket

Strona 48 - 6.5 Logs

Chapter 7 Utility IP Power Manager has provided a utility for customer to set the IP address and upgrade. You can find this utility in “Utility” fold

Strona 49 - 6.5.2 Event

- 39 - with the located firmware. Open Press this button to locate the firmware. Quit Close utility.

Strona 50

Appendix A Error Code Error Code Description E01 Network link down E02 Parameters checksum error E03 Input voltage over threshold high (Volt) E04 I

Strona 51

Appendix B Specification Model IPM-8001-US IPM-8002-EU IPM-8002-UK LAN Port 10/100Mbps, RJ-45 Console port RJ-45 connector x 1 COM port 1; For UPS c

Strona 52 - Chapter 7 Utility

- 42 - Appendix C Glossary Authentication Authentication refers to the verification of a transmitted message's integrity. DHCP DHCP (Dynamic Ho

Strona 53

- 43 - network. Every client and server station must have a unique IP address. Clients are assigned either a permanent address or have one dynamicall

Strona 54 - Appendix A Error Code

- 44 - and forwards mail. SNMP SNMP (Simple Network Management Protocol) is a widely used network monitoring and control protocol. SNMP hardware or s

Strona 55 - Appendix B Specification

Chapter 1 Introduction Thank you for purchasing PLANET IP Power Manager. This manual guides you on how to install and properly use the IP Power Manag

Strona 56 - Appendix C Glossary

z Upgrade utility for easy firmware upgrade z Event notification through SNMP trap or E-Mail alerts z Daily history report through E-mail z Suppo

Strona 57

LED Function Description 1 Current level indicator Displays the amount of current being drawn by the connected output device through the power out

Strona 58

LED Function Description INPUT Input power consumption indicator Displays the amount of current being drawn by the connected output device through

Komentarze do niniejszej Instrukcji

Brak uwag